MP200 System
  • MP200 System

  • Next Generation System for Life Science Research

  • Product No: NS-1096
  • Manufacturer: Biopac
  • EMG ECG EOG MRI Respiratory Airflow HR HRV
  • Request Quote

Description

The MP200 Data Acquisition System is a versatile and advanced solution designed for life science research. Building upon the robust foundation of the MP160 system, the MP200 offers enhanced performance and expanded capabilities to meet the evolving needs of researchers.

System Features

  • High-Speed Data Acquisition: The MP200 system supports aggregate sampling rates of up to 400 kHz, enabling precise capture of rapid physiological events.
  • Enhanced Connectivity: Utilizing Ethernet (UDP) communication, the MP200 ensures seamless integration with both Windows and Mac operating systems, facilitating flexible data management.
  • Modular Design: The system's modular architecture allows for easy expansion and customization, accommodating a wide range of research applications.
  • Comprehensive Software Integration: Paired with AcqKnowledge software, the MP200 provides powerful data analysis tools, including automated routines for ECG, HRV, EEG, EMG, and more.

Included Components

  • MP200 Data Acquisition Unit
  • HLT100C Interface Module
  • AcqKnowledge Software License (iLok USB)
  • ETHUSB Ethernet Adapter and Crossover Cable
  • Power Supply

Please note: The MP200 system is intended for research applications only and is not classified as a medical device under EU directive 93/42/EEC. It is not designed or intended for use in the diagnosis or treatment of disease.

Technical Specifications

Device

Max Sample Rate, MP Internal Memory: 

100 kHz per channel

PC Memory/Disk:

200 K samples/sec (400 K aggregate)

Internal Buffer:

Approximately 42 million samples

Waveform Output Buffer:

Approximately 4.2 million samples

Serial Interface Type/Rate:

Ethernet: UDP (10M bits/sec)

Transmission Type:

Ethernet

Maximum cable length:

100 meters (Ethernet cable)

Power Requirements:

12 VDC @ 2.5 amp (uses AC150A)

Dimensions:

10 cm x 11 cm x 19 cm

Weight:

1.119 kg

Operating Temperature Range:

0-70° C

Operating Humidity Range:

0-95%

OS Compatibility:

Ethernet Interface:
Windows: Windows XP, Vista, 7, 8.x, 10
Mac: OS X
USB Interface:
Windows: Not yet supported
Mac: Not yet supported

Analog Inputs

Number of Channels:

16

Absolute Maximum Input:

±15 V

Operational Input Voltage:

±10 V

A/D Resolution:

16 Bits

Accuracy (% of FSR):

±0.00076

Input impedance:

1.0 MΩ

 

Analog Outputs

Number of Channels:

2

Max output with acquisition:

2 channels

Output Voltage Range:

±10 V

D/A Resolution:

16 bits

Accuracy (% of FSR):

±0.00076

Output Drive Current:

±5 mA (max)

Output Impedance:

100 Ω

 

Digital I/O

Number of Channels:

16

Voltage Levels:

TTL, CMOS

Digital I/O Logic Type:

CMOS

Input Voltage Range:

-0.5 V to 5.5 V (maximum)

Input Clamp Current:

±20 mA (max)

Output Drive Current:

±20 mA (max)

External Trigger Input:

TTL, CMOS compatible

Logic Level Thresholds:

Input Low Voltage: 1.50 V (max)
Input High Voltage: 3.45 V (min)

 

Time Base

Min Sample Rate:

0.1 Hz (6 samples per minute)

Trigger Options:

Internal, External or Signal Level

 

Power

Amplifier Module Isolation:

Provided by the MP unit, isolated clean power

CE Marking:

Complies with EC Low Voltage and EMC Directives

Leakage current: ​​​​​​

<8 µA (Normal), <400 µA (Single Fault)

Fuse:

Polymeric PTC resettable fuse, 24 V/3 A

 

Please note: Important! This product is for research applications only. Not a medical device as defined in EU directive 93/42/EEC. Not designed or intended to be used for diagnosis or treatment of disease.